Release notes 1.11
Note
Newest version in this series: 1.11.0. Earlier versions are described on the page Release notes 1.10.
This page lists all versions of PlantBeat 1.11, newest first. Each version is divided into New, Improvements, Fixed and Important notes, each sorted by product area. A version always includes all changes of the versions below it and of the 1.10 series.
1.11.0
Date follows with the release
New in 1.11.0
Box
Type plate and serial number
The QR code on the type plate of the PlantBeat Box opens the initial setup with the setup code already filled in. The box shows its serial number in the device card, in the diagnostics and in the support package.
PLCs and drivers
Beckhoff TwinCAT 3
PlantBeat reads and writes values from Beckhoff PLCs via ADS. Dashboards, history, alarms, controls and reading with enable flag and done flag (per group, e.g. GVL or program) work as with Siemens. In the connection wizard, you choose the manufacturer, and PlantBeat suggests the AmsNetId. You create the route for PlantBeat on the PLC yourself, and a guide shows you how. With the address "demo", you can try out Beckhoff without a PLC.
PLC diagnostics
PlantBeat reads the diagnostic buffer of the S7 regularly and stores it permanently, on the "Diagnostic buffer" page with filter, search, CSV export and descriptions as in the TIA Portal. If the CPU goes to STOP, an alarm with mail follows after a few seconds, and an all-clear as soon as it runs again. The connection list shows the status LEDs RUN/STOP, ERROR and MAINT as on the CPU.
PLC certificate
For secured S7-1500, PlantBeat checks the certificate of the CPU before the CPU password is sent. You confirm it once in the "PLC certificate" window. If it changes, recording stops until you confirm the new certificate. With the option "Keep recording after a certificate change until confirmed", recording continues for the set transition period (1 to 7 days). Badges show the status, and a warning appears 30 and 7 days before expiry. The "Evidence report" button on the "Connections" page creates a printable report on all certificates for administrators.
Connection wizard
You set up new connections in three steps: Connection, Variables, Selected variables. The symbol tree has a search and the switch "HMI-visible variables only". For each variable, you set name, unit, scaling and statistics. "Edit" opens the selected variables directly, without reading the PLC again.
Reports and export
PlantBeat API (OData)
MES, ERP, spreadsheets, analytics tools and your own scripts read values, measured values, alarms, data records and minute, hourly and daily values over HTTPS: on every installation its own data, on the master the data of all lines. You create access entries with their own key, expiry date and line selection under "Settings" → "Data" → "API access". Every access is logged. There, the "OpenAPI description (openapi.json)" button downloads the description for common API tools, on the PlantBeat Box as soon as HTTPS is turned on. Learn more in Interface (API).
Federation
PlantBeat Federation
Several PlantBeat installations in one plant work together. Each line records on its own PlantBeat Box and sends measured values, alarms and data records to a master (PlantBeat on Windows or a PlantBeat Box), where the values of all lines are available in dashboards, reports, alarms and the designer. If the network fails, the line keeps recording and catches up without gaps. If a line stops reporting, the master sends a mail. On the "Federation" page, you pair lines with a pairing code and a check code, see the state and backlog of each line, and open its data with "Open the line's data". On the line, you choose under "Settings" → "Data" → "Federation" which values are passed on. Operating from the master only works if "Access from the master" on the line is set to "View and operate", the value is enabled under "Operable from the master", and a user with "Operate" is signed in on the master. Every operation is logged on the line. The master needs the "PlantBeat Master" license, the lines their normal license. Learn more in PlantBeat Federation.
PlantBeat AI
PlantBeat AI (preview)
The AI assistant on the PlantBeat Box M and L creates and changes dashboards and answers questions about values, alarms and data records. It runs entirely on the box, no request leaves the device, and it respects the user's permissions. You can reverse every change with "Undo". You turn it on and choose the "Fast" or "Thorough" mode under "Settings" → "AI". As a preview, it still has limits: Ask follow-up questions in full, give periods with a date, the search for data records is limited, and please check the answers. Learn more in PlantBeat AI.
Improvements in 1.11.0
Box
- Packet filter by default – Only the user interface (HTTP 80, HTTPS 443, also for API and Federation),
plantbeat.localand ping are reachable from the network, and the maintenance access only from private networks. - Protected system jobs – Jobs from the user interface to the system (network, time, support access, backup, factory reset) run through a separate, protected path, and the license key is removed from the boot partition after activation.
- Fixed permissions and security updates – The program files get fixed permissions with every update, and critical security updates of the operating system come with the PlantBeat update when needed.
PLCs and drivers
- PLC password – If the PLC password is missing or wrong, PlantBeat says so clearly. With a wrong password, recording stops immediately so that no further failed sign-ins occur on the CPU.
Values and recording
- Long periods in the history – The history also shows long periods completely, condensed to averages per day, hour or minute.
- Transport security for the external data store – New targets connect encrypted and check the certificate of the database server, optionally with your own CA or fingerprint. Certificate errors during the connection test are explained in plain language.
Dashboards
- Designer and time filters – The designer saves every change immediately, and time filters only offer matching tiles as targets.
Alarms and maintenance
- Confirmation before shortening – Retention and upper limit ask for confirmation before shortening.
Users and security
- No secrets in logs – Passwords, tokens and keys no longer appear in the support package and in the log download.
- HTTPS certificate – If the self-generated HTTPS certificate is unreadable, PlantBeat creates a new one once instead of at every start. Browsers no longer have to trust it again and again.
Operation and updates
- Signed updates – The box and the Windows app only install update packages with a valid signature and never an older version. The update to 1.11 brings the check with it. You do not need to do anything.
- Settings – The settings are organized into six sections with navigation and search. Sections that need action are marked.
- Consistent user interface – Consistent icons instead of emojis, the browser tab shows the name of the page, and the English user interface is fully translated.
Windows
- Failed update – If an update fails, setup starts PlantBeat or the service again.
- Data directory – The data directory stays under
%ProgramData%\Smartlife\SelfService. New installations secure it automatically.
Fixed in 1.11.0
Values and recording
- Fixed: Minor corrections to data records.
Dashboards
- Fixed: Color selection, alarm condition "above"/"below", operators of conditional formatting and the chart type list in the designer.
- Fixed: Several designer windows no longer overwrite each other.
- Fixed: Heat map, state text on yes/no values, value table and legend of the snapshot.
Alarms and maintenance
- Fixed: Alarm episodes always have an end, even after a limit jump, a rule change or a restart.
Users and security
- Fixed: Reloading after sign-in no longer counts as a failed attempt.
Operation and updates
- Fixed: No more page errors when switching tabs.
- Fixed: Dialogs no longer close by themselves.
- Fixed: Minor corrections on narrow screens.
PlantBeat AI
- Fixed: No more page errors after a change by PlantBeat AI.
Licenses and customer portal
- Fixed: An unreadable license file no longer shuts down PlantBeat.
Important notes on 1.11.0
Box
- Port 5210 internal only – Port 5210 is now only reachable internally. Open the user interface via
plantbeat.localor the address of the box.
PLCs and drivers
- Retention of the diagnostic buffer – By default, nothing is deleted. If needed, you set an upper limit per connection under "Settings" → "Data" → "Data retention".
Warning
Confirm certificate – Existing secured S7-1500 keep recording after the update until someone confirms the certificate. Please check and confirm the certificate for every secured connection. The texts from the CPU's web server in the diagnostic buffer only appear after that.
Warning
Beckhoff in the plant network – Without an installed TwinCAT, PlantBeat uses a built-in ADS router without ADS Secure. So run Beckhoff connections in an isolated plant network. For now, the "Records" page is only available for Siemens.
Values and recording
- Existing storage targets – Existing targets of the external data store behave as before and show a notice. Switch them to a verified connection under "Change storage target…".
Users and security
- Additional host names – If you open PlantBeat through your own DNS name, enter it under "Settings" → "Access protection" → "Additional host names". As long as access without sign-in is possible (e.g. wall displays), PlantBeat rejects other names to protect against DNS rebinding.
plantbeat.local, IP addresses,localhost, the device name and your HTTPS domain work without an entry. The card shows rejected names so you can add them.
Warning
Initial setup and access protection – A new PlantBeat Box starts with setup. With the setup code from the label, you create the first administrator, and access protection is then active. On Windows, setup only works on the computer itself. Existing installations keep running unchanged but show the bar "Switch on access protection now". Please turn it on. If your box has no code on the label, a factory reset with the button opens setup for 30 minutes without a code.
Federation
- Federation and API – After the update, nothing changes as long as you do not create API access and do not set up an installation as master or line. On Windows, both use their own HTTPS port (5211), which setup opens in the firewall for the "Private" and "Domain" network profiles, effective after a restart of PlantBeat. If the master's network is set to "Public", switch it to "Private" or "Domain". For a different port, you create a firewall rule yourself. On the PlantBeat Box, both run over HTTPS ("Settings" → "Access & security"). The data backup contains Federation settings and API access entries, but not the pairing: You pair a replaced line again.
Windows
- Jobs only on the box – Jobs that only concern the box (network, time, support access, backup, factory reset) are no longer available on Windows.
- Permissions of the data directory – Existing installations keep their permissions. If the diagnostics tab reports the data directory as writable, have your IT secure the folder as described in chapter 7 of the manual.
Licenses and customer portal
- License and updates – New versions do not need a new license. The license card shows how long updates are covered as "Updates until …". The entitlement comes automatically from the license server, without internet via the browser or as a file from the customer portal. If the running version is not covered by "Updates until", the license has expired, or the clock was set back, PlantBeat no longer connects real PLCs. Demo connections and the user interface stay usable, and the banner gives the reason. Automatic updates skip versions that are not covered.
- Clock release – If the clock is wrong, a clock release helps, automatically when online, otherwise with the clock code through support.
- Trial mode – You can restart the trial mode without a license at the earliest 24 hours after the last one.