Troubleshooting and FAQ
This page lists the most common questions and what helps, sorted by topic. If you can't find your question, send us a support package (see below) through the support form.
Topics
| Topic | Typical questions |
|---|---|
| PLC connection | Connection stays "Disconnected", CPU password, certificate, missing variables, writing does not work |
| Recording | Values missing from the history, values "frozen", data records do not arrive, storage running low |
| Sign-in | Sign-in locked after failed attempts, forgotten password, setup code, DNS name rejected |
| Clock and clock code | Wrong time, PLCs disconnected after a clock jump, clock release without internet |
| Updates | Update is not installed, check failed, installation refused |
| License | Trial mode expired, version not covered, messages during activation |
| No e-mails, test e-mail failed, send failure, e-mails from the Federation |
User interface
The user interface does not load
- Box: Enter
http://plantbeat.localin the browser, without a port. If that does not work, use the IP address of the Box, for examplehttp://192.0.2.20, or the fallback addresshttp://plantbeat/. If there is a second Box on the same network, it is calledplantbeat-2.local. - Box from 1.11: Port 5210 can no longer be reached from the network. Delete bookmarks with
:5210and open the Box without a port. - Windows: Enter
http://localhost:5210on the computer itself. If PlantBeat runs as a Windows service, check in the Services console that the "PlantBeat" service is running. - If the green LED on the Box is solid on, the Box is still starting. Wait until it blinks slowly.
The browser warns about the certificate
Over https://, the browser warns once on the first visit because PlantBeat issues its own certificate. This is normal, and the connection is still encrypted. To avoid the warning, upload your own certificate under Settings, section "Access & security", card "Secure connection (HTTPS)". See Secure connection (HTTPS).
A page is missing from the left sidebar, or "No permission" appears
Your role is not sufficient for this page. An administrator changes it on the Users page. The change takes effect immediately.
Box and network
The Box is gone after setting a static address
The new address first applies on a trial basis only. Without confirmation, the Box restores the previous settings on its own after the confirmation window (2, 5 or 10 minutes). If you need it faster: hold the button for 5 to 7 seconds until the green LED blinks fast, then release it. Both ports switch to DHCP. Make sure you release the button before the red LED blinks fast: after 15 seconds, releasing it triggers the factory reset. See Network.
The red LED is solid on
No connection to a PLC has been set up on the Box yet. If it blinks slowly, a connection has a fault. See LEDs and button.
The green LED blinks fast
PlantBeat reports a device fault. Open the Diagnostics page. The cause is shown at the top.
Send a support package
- Open the Diagnostics page and click Download support files in the "Support package" card. The package contains logs, diagnostics and settings without passwords.
- Send the ZIP file with a short description and the serial number of the Box through the support form. By e-mail, you can reach us at [email protected].
If the error only occurs now and then, set the log level to "Debug" first, see Diagnostics and support.