Updates

Updated: from version 1.11

All update settings are under Settings, section "System", card "Updates". See Updates.

An update is not installed

  • Time window: If "Only install within a time window" is on, PlantBeat waits for the next window. The card shows "Next possible installation: …". If it shows "No valid window — please check the times.", From and To are the same or invalid.
  • Automatic installation off: If "Automatic installation is turned off" is shown, you install by hand with Install version … now.
  • Not covered: "New version … available, but not covered by your update subscription – it will not be installed automatically." If you install it anyway, PlantBeat no longer connects to real PLCs afterwards. See License.

"Check failed: …"

PlantBeat cannot reach the license server. Check access to license.plantbeat.io and download.plantbeat.io in the firewall, see Firewall rules. The card names the reason and shows "Please check whether … is reachable."

"Update failed (…)."

The reason is shown in parentheses. From version 1.11, the Box and Windows only install update packages with a valid signature and never a version older than the running one. If the signature is missing or does not match, you see, for example:

  • "Update is not signed – installation refused"
  • "Update signature is invalid – installation refused"
  • "Installer no longer matches the signed checksum – not started"

In that case, the package was changed on the way or does not come from PlantBeat. The running version stays unchanged. Try again later. If the message comes back, send a support package to support, see Troubleshooting and FAQ.

Note

If an update fails on Windows, the setup restarts PlantBeat or the service on its own.

The user interface is briefly gone after the update

The installation restarts the application. During this short time, PlantBeat does not record and the user interface cannot be reached. Reload the page after about one minute.

After the update to 1.11

  • Box: Port 5210 can no longer be reached from the network. Open the Box through http://plantbeat.local or its address without a port.
  • "Switch on access protection now" bar: Existing installations keep running without sign-in. Switch on access protection, see Users and roles.
  • Secured S7-1500: Confirm the PLC certificate for every secured connection, see Secured S7-1500 with TLS.

Next steps